Multi-Vari Chart

Overview | How to | Example

 


 

Overview

The Multi-Vari chart is used to display ANOVA data for up to 4 factors. It is commonly used as a preliminary analysis of the data to assess the means for each factor level. Each factor should have at least 2 distinct levels.

 


 

How to

At the Excel Menu (For Excel 2007, go to Add-ins first)

  1. Choose ProcessMA > Graphs > Multi-Vari Chart

  2. In Variable, select the column containing the response data (Numeric)

  3. In Factor 1 , select the column containing factor levels of the first factor (>=2 distinct values)

  4. In Factor 2 , select the column containing factor levels of the second factor (Optional, >=2 distinct values)

  5. In Factor 3 , select the column containing factor levels of the third factor (Optional, >=2 distinct values)

  6. In Factor 4 , select the column containing factor levels of the fourth factor (Optional, >=2 distinct values)

  7. Click OK

 

 

Example

You conducted an experiment to study how well organisms multiple in different temperatures and in the presence of different catalysts. You prepared 18 dishes of organisms and placed them at three different temperatures and added three different types of catalyst. You recorded the number of organism in each dish after 10 days. You want to visualise the data to see if there are any trends and interactions.

  1. Open data worksheet by choosing ProcessMA > Tools > Data

  2. Choose ProcessMA > Graphs > Multi-Vari Chart

  3. In Variable, select L - Organism

  4. In Factor 1 , select M - Temperature

  5. In Factor 2 , select N - Catalyst

  6. Click OK

 

Results & Interpretation

 

 


 

Copyright © ProcessMA